{"product_id":"silicon-hose-3m","title":"Silicone Tubing - 3m","description":"\u003ch3 data-start=\"378\" data-end=\"775\"\u003eThis platinum-cured silicone tubing (Size \u003cstrong data-start=\"420\" data-end=\"427\"\u003e35#\u003c\/strong\u003e) is engineered for high-precision peristaltic pump applications.\u003c\/h3\u003e\n\u003cp data-start=\"378\" data-end=\"775\"\u003eIt is the recommended and validated tubing for \u003cstrong data-start=\"544\" data-end=\"562\"\u003eTveskaeg® Analyzers\u003c\/strong\u003e, ensuring reliable sample intake and stable delivery to the instrument’s internal measurement chamber. Manufactured by FedroTek, this tubing is designed to provide excellent elasticity, clarity, and durability—critical for long-term analytical workflows.\u003c\/p\u003e\n\u003cp data-start=\"777\" data-end=\"1000\"\u003eManufacturer reference: \u003ca data-start=\"955\" data-end=\"1000\" rel=\"noopener\" class=\"decorated-link\" href=\"https:\/\/www.fedrotek.com\/productlist-272.html\"\u003ehttps:\/\/www.fedrotek.com\/productlist-272.html\u003c\/a\u003e\u003c\/p\u003e\n\u003ch4 data-start=\"1007\" data-end=\"1027\"\u003e\u003cstrong data-start=\"1011\" data-end=\"1027\"\u003eKey Features\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1028\" data-end=\"1513\"\u003e\n\u003cli data-start=\"1028\" data-end=\"1074\"\u003e\n\u003cp data-start=\"1030\" data-end=\"1074\"\u003e\u003cstrong data-start=\"1030\" data-end=\"1072\"\u003ePlatinum-cured, medical-grade silicone\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1075\" data-end=\"1092\"\u003e\n\u003cp data-start=\"1077\" data-end=\"1092\"\u003e\u003cstrong data-start=\"1077\" data-end=\"1086\"\u003eSize:\u003c\/strong\u003e 35#\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1093\" data-end=\"1139\"\u003e\n\u003cp data-start=\"1095\" data-end=\"1139\"\u003e\u003cstrong data-start=\"1095\" data-end=\"1122\"\u003eInternal Diameter (ID):\u003c\/strong\u003e 5\/16\" (7.9 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1140\" data-end=\"1183\"\u003e\n\u003cp data-start=\"1142\" data-end=\"1183\"\u003e\u003cstrong data-start=\"1142\" data-end=\"1166\"\u003eOuter Diameter (OD):\u003c\/strong\u003e 1\/2\" (12.7 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1184\" data-end=\"1222\"\u003e\n\u003cp data-start=\"1186\" data-end=\"1222\"\u003e\u003cstrong data-start=\"1186\" data-end=\"1205\"\u003eWall Thickness:\u003c\/strong\u003e 3\/32\" (2.4 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1223\" data-end=\"1297\"\u003e\n\u003cp data-start=\"1225\" data-end=\"1297\"\u003e\u003cstrong data-start=\"1225\" data-end=\"1257\"\u003eHigh elasticity and softness\u003c\/strong\u003e for smooth peristaltic pump operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1298\" data-end=\"1349\"\u003e\n\u003cp data-start=\"1300\" data-end=\"1349\"\u003e\u003cstrong data-start=\"1300\" data-end=\"1322\"\u003eTransparent tubing\u003c\/strong\u003e with a smooth inner wall\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1350\" data-end=\"1394\"\u003e\n\u003cp data-start=\"1352\" data-end=\"1394\"\u003e\u003cstrong data-start=\"1352\" data-end=\"1392\"\u003eLow protein adhesion and penetration\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1395\" data-end=\"1470\"\u003e\n\u003cp data-start=\"1397\" data-end=\"1470\"\u003eExcellent resistance to \u003cstrong data-start=\"1421\" data-end=\"1468\"\u003eUV, ozone, chemicals, high\/low temperatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1471\" data-end=\"1513\"\u003e\n\u003cp data-start=\"1473\" data-end=\"1513\"\u003e\u003cstrong data-start=\"1473\" data-end=\"1495\"\u003eTemperature range:\u003c\/strong\u003e –30°C to +200°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1520\" data-end=\"1549\"\u003e\u003cstrong data-start=\"1524\" data-end=\"1549\"\u003eRegulatory Compliance\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"1550\" data-end=\"1620\"\u003eMeets a wide range of international and food-contact safety standards:\u003c\/p\u003e\n\u003cul data-start=\"1622\" data-end=\"1868\"\u003e\n\u003cli data-start=\"1622\" data-end=\"1655\"\u003e\n\u003cp data-start=\"1624\" data-end=\"1655\"\u003e\u003cstrong data-start=\"1624\" data-end=\"1653\"\u003eUSP Class VI (USP43 \u0026lt;88\u0026gt;)\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1656\" data-end=\"1681\"\u003e\n\u003cp data-start=\"1658\" data-end=\"1681\"\u003e\u003cstrong data-start=\"1658\" data-end=\"1679\"\u003eEU RoHS Directive\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1682\" data-end=\"1711\"\u003e\n\u003cp data-start=\"1684\" data-end=\"1711\"\u003e\u003cstrong data-start=\"1684\" data-end=\"1709\"\u003eEU REACH requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1712\" data-end=\"1742\"\u003e\n\u003cp data-start=\"1714\" data-end=\"1742\"\u003e\u003cstrong data-start=\"1714\" data-end=\"1740\"\u003eUS FDA 21 CFR 177.2600\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1743\" data-end=\"1797\"\u003e\n\u003cp data-start=\"1745\" data-end=\"1797\"\u003e\u003cstrong data-start=\"1745\" data-end=\"1795\"\u003eGB4806.11-2016 – National Food Safety Standard\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1798\" data-end=\"1868\"\u003e\n\u003cp data-start=\"1800\" data-end=\"1868\"\u003e\u003cstrong data-start=\"1800\" data-end=\"1868\"\u003eGB15979-2002 – Hygiene Standard for Disposable Sanitary Products\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"1875\" data-end=\"1907\"\u003e\u003cstrong data-start=\"1879\" data-end=\"1907\"\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul data-start=\"1908\" data-end=\"2121\"\u003e\n\u003cli data-start=\"1908\" data-end=\"1939\"\u003e\n\u003cp data-start=\"1910\" data-end=\"1939\"\u003e\u003cstrong data-start=\"1910\" data-end=\"1923\"\u003eHardness:\u003c\/strong\u003e Shore A 50–55\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1940\" data-end=\"1975\"\u003e\n\u003cp data-start=\"1942\" data-end=\"1975\"\u003e\u003cstrong data-start=\"1942\" data-end=\"1963\"\u003eTensile Strength:\u003c\/strong\u003e ≥ 7.0 MPa\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1976\" data-end=\"2011\"\u003e\n\u003cp data-start=\"1978\" data-end=\"2011\"\u003e\u003cstrong data-start=\"1978\" data-end=\"2002\"\u003eElongation at Break:\u003c\/strong\u003e ≥ 500%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2012\" data-end=\"2046\"\u003e\n\u003cp data-start=\"2014\" data-end=\"2046\"\u003e\u003cstrong data-start=\"2014\" data-end=\"2032\"\u003eTear Strength:\u003c\/strong\u003e ≥ 30.0 kN\/m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2047\" data-end=\"2073\"\u003e\n\u003cp data-start=\"2049\" data-end=\"2073\"\u003e\u003cstrong data-start=\"2049\" data-end=\"2059\"\u003eColor:\u003c\/strong\u003e Transparent\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2074\" data-end=\"2121\"\u003e\n\u003cp data-start=\"2076\" data-end=\"2121\"\u003e\u003cstrong data-start=\"2076\" data-end=\"2103\"\u003eTemperature Resistance:\u003c\/strong\u003e –30°C to +200°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 data-start=\"2128\" data-end=\"2160\"\u003e\u003cstrong data-start=\"2132\" data-end=\"2160\"\u003eApplication in Tveskaeg®\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp data-start=\"2161\" data-end=\"2229\"\u003eThis tubing is used in the \u003cstrong data-start=\"2188\" data-end=\"2225\"\u003eTveskaeg® peristaltic pump system\u003c\/strong\u003e to:\u003c\/p\u003e\n\u003cul data-start=\"2230\" data-end=\"2484\"\u003e\n\u003cli data-start=\"2230\" data-end=\"2267\"\u003e\n\u003cp data-start=\"2232\" data-end=\"2267\"\u003eDraw the sample into the analyzer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2268\" data-end=\"2336\"\u003e\n\u003cp data-start=\"2270\" data-end=\"2336\"\u003eDeliver the sample precisely to the internal measurement chamber\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2337\" data-end=\"2411\"\u003e\n\u003cp data-start=\"2339\" data-end=\"2411\"\u003eMaintain a stable and continuous flow path for near-real-time analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2412\" data-end=\"2484\"\u003e\n\u003cp data-start=\"2414\" data-end=\"2484\"\u003eSupport both \u003cstrong data-start=\"2427\" data-end=\"2453\"\u003econtinuous measurement\u003c\/strong\u003e and \u003cstrong data-start=\"2458\" data-end=\"2471\"\u003ePump Mode\u003c\/strong\u003e operations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2486\" data-end=\"2610\"\u003eIt is the recommended replacement tubing for maintaining optimal fluid handling performance in all Tveskaeg® configurations.\u003c\/p\u003e\n\u003ch4 data-start=\"2486\" data-end=\"2610\"\u003eShipping\u003c\/h4\u003e\n\u003cp data-start=\"2486\" data-end=\"2610\"\u003e\u003cstrong\u003eUnit Size \u0026amp; Weight:\u003c\/strong\u003e 39 x 30 x 19 cm - 1 kg\u003c\/p\u003e\n\u003cp data-start=\"2486\" data-end=\"2610\"\u003eAll accessories are shipped via \u003cstrong\u003eDHL Express\u003c\/strong\u003e to all destinations. Shipping rates are calculated automatically at checkout based on destination and order details. Orders are typically shipped within \u003cstrong\u003e1–3 business days\u003c\/strong\u003e after order confirmation. Availability is limited, and items may sell out without prior notice.\u003c\/p\u003e","brand":"NanoNord Online Store","offers":[{"title":"Default Title","offer_id":56172048679237,"sku":"4004","price":120.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0996\/3169\/4149\/files\/silic_tube_3m_01.jpg?v=1762960384","url":"https:\/\/shop.nanonord.com\/products\/silicon-hose-3m","provider":"NanoNord Shop","version":"1.0","type":"link"}